Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/100mA
Make Autodata
Type TR-95/100
Power 10.35 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 14 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 100 mA
Output Power 9.5 kW
Efficiency 89%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 440litres
Dielectric strength of oil (with 2.5mm) 60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 500 W (Subject to IS tolerance)
Load losses (Short Circuit) 400 W (Subject to IS tolerance)
Miscellaneous losses if any 300 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator and breather
HT Bushing orientation Horizontal
Earthing Switch Inbuilt
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 9.5 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 100 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/100
Rated voltage output 415 V
Rated Current output 14 Amps
Rated frequency 50 Hz
Heat dissipation of panel 150 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 55A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication Default RS485 Modbus communication

Open communication is optional
HMI 4.3" Snowy IV Touch screen display unit for single field

7" Hadock Touch screen display unit for Multiple field
Built in Rapper provision Provided (Optional)

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/150mA
Make Autodata
Type TR-95/150
Power 15.25 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 21 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 150 mA
Output Power 14.25 kW
Efficiency 90%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 440litres
Dielectric strength of oil (with 2.5mm) 60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 500 W (Subject to IS tolerance)
Load losses (Short Circuit) 700 W (Subject to IS tolerance)
Miscellaneous losses if any 400 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator and breather
HT Bushing orientation Horizontal
Earthing Switch Inbuilt
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 14.25 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 150 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/150
Rated voltage output 415 V
Rated Current output 21 Amps
Rated frequency 50 Hz
Heat dissipation of panel 200 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 55A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/150mA
Make Autodata
Type TR-95/150
Power 15.25 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 21 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 150 mA
Output Power 14.25 kW
Efficiency 90%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 440litres
Dielectric strength of oil (with 2.5mm) 60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 500 W (Subject to IS tolerance)
Load losses (Short Circuit) 700 W (Subject to IS tolerance)
Miscellaneous losses if any 400 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator and breather
HT Bushing orientation Horizontal
Earthing Switch Inbuilt
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 14.25 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 150 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/150
Rated voltage output 415 V
Rated Current output 21 Amps
Rated frequency 50 Hz
Heat dissipation of panel 200 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 55A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/200mA
Make Autodata
Type TR-95/200
Power 20.7 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 29 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 200 mA
Output Power 19 kW
Efficiency 91%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 440litres
Dielectric strength of oil (with 2.5mm) 60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 500 W (Subject to IS tolerance)
Load losses (Short Circuit) 800 W (Subject to IS tolerance)
Miscellaneous losses if any 450 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator and breather
HT Bushing orientation Horizontal
Earthing Switch Inbuilt
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 19 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 200 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/200
Rated voltage output 415 V
Rated Current output 29 Amps
Rated frequency 50 Hz
Heat dissipation of panel 200 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 55A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/250mA
Make Autodata
Type TR-95/250
Power 25.6 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 36 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 250 mA
Output Power 23.75 kW
Efficiency 90%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 440litres
Dielectric strength of oil (with 2.5mm) >60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 500 W (Subject to IS tolerance)
Load losses (Short Circuit) 1300 W (Subject to IS tolerance)
Miscellaneous losses if any 700 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator without breather
HT Bushing orientation Horizontal
Earthing Switch Inbuilt
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 23.75 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 250 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/250
Rated voltage output 415 V
Rated Current output 36 Amps
Rated frequency 50 Hz
Heat dissipation of panel 250 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 90A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/300mA
Make Autodata
Type TR-95/300
Power 30.5 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 42 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 300 mA
Output Power 28.5 kW
Efficiency 92%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 440litres
Dielectric strength of oil (with 2.5mm) >60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 500 W (Subject to IS tolerance)
Load losses (Short Circuit) 1100 W (Subject to IS tolerance)
Miscellaneous losses if any 600 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator without breather
HT Bushing orientation Horizontal
Earthing Switch Inbuilt
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 28.5 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 300 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/300
Rated voltage output 415 V
Rated Current output 42 Amps
Rated frequency 50 Hz
Heat dissipation of panel 250 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 90A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/400mA
Make Autodata
Type TR-95/400
Power 41.4 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 58 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 400 mA
Output Power 38 kW
Efficiency 92%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 480litres
Dielectric strength of oil (with 2.5mm) >60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 600 W (Subject to IS tolerance)
Load losses (Short Circuit) 1500 W (Subject to IS tolerance)
Miscellaneous losses if any 750 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator without breather
HT Bushing orientation Horizontal
Earthing Switch Inbuilt
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 38 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 400 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/400
Rated voltage output 415 V
Rated Current output 58 Amps
Rated frequency 50 Hz
Heat dissipation of panel 350 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 110A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/600mA
Make Autodata
Type TR-95/600
Power 62 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 86 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 600 mA
Output Power 57 kW
Efficiency 93%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 580litres
Dielectric strength of oil (with 2.5mm) 60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 700 W (Subject to IS tolerance)
Load losses (Short Circuit) 2400 W (Subject to IS tolerance)
Miscellaneous losses if any 900 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator and breather
HT Bushing orientation Horizontal
Earthing Switch Inbuilt
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 57 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 600 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/600
Rated voltage output 415 V
Rated Current output 86 Amps
Rated frequency 50 Hz
Heat dissipation of panel 550 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 160A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/700mA
Make Autodata
Type TR-95/700
Power 73 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 102 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 700 mA
Output Power 66.5 kW
Efficiency 93%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 600litres
Dielectric strength of oil (with 2.5mm) 60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 800 W (Subject to IS tolerance)
Load losses (Short Circuit) 2800 W (Subject to IS tolerance)
Miscellaneous losses if any 1000 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator and breather
HT Bushing orientation Horizontal
Earthing Switch Inbuilt
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 66.5 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 700 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/700
Rated voltage output 415 V
Rated Current output 102 Amps
Rated frequency 50 Hz
Heat dissipation of panel 600 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 250A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/800mA
Make Autodata
Type TR-95/800
Power 82 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 114 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 800 mA
Output Power 76 kW
Efficiency 93%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 640 litres
Dielectric strength of oil (with 2.5mm) 60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 900 W (Subject to IS tolerance)
Load losses (Short Circuit) 3300 W (Subject to IS tolerance)
Miscellaneous losses if any 1400 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator without breather
HT Bushing orientation Horizontal
Earthing Switch Inbuilt Manual
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 76 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 800 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/800
Rated voltage output 415 V
Rated Current output 114 Amps
Rated frequency 50 Hz
Heat dissipation of panel 700 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 250A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/900mA
Make Autodata
Type TR-95/900
Power 92.6 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 129 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 900 mA
Output Power 85.5 kW
Efficiency 93%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 680 litres
Dielectric strength of oil (with 2.5mm) 60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 1000 W (Subject to IS tolerance)
Load losses (Short Circuit) 3500 W (Subject to IS tolerance)
Miscellaneous losses if any 1500 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator without breather
HT Bushing orientation Horizontal
Earthing Switch Inbuilt Manual
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 85.5 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 900 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/900
Rated voltage output 415 V
Rated Current output 129 Amps
Rated frequency 50 Hz
Heat dissipation of panel 750 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 250A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/1000mA
Make Autodata
Type TR-95/1000
Power 103 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 143 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 1000 mA
Output Power 95 kW
Efficiency 93%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 700litres
Dielectric strength of oil (with 2.5mm) 60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 1100 W (Subject to IS tolerance)
Load losses (Short Circuit) 3800 W (Subject to IS tolerance)
Miscellaneous losses if any 1600 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator without breather
HT Bushing orientation Horizontal
Earthing Switch External Manual
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 95 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 1000 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/1000
Rated voltage output 415 V
Rated Current output 143 Amps
Rated frequency 50 Hz
Heat dissipation of panel 800 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 250A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/1200mA
Make Autodata
Type TR-95/1200
Power 123.4 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 172 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 1200 mA
Output Power 114 kW
Efficiency 93%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 720litres
Dielectric strength of oil (with 2.5mm) 60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 1200 W (Subject to IS tolerance)
Load losses (Short Circuit) 4600 W (Subject to IS tolerance)
Miscellaneous losses if any 1800 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator without breather
HT Bushing orientation Horizontal
Earthing Switch External Manual
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 114 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 1200 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/1200
Rated voltage output 415 V
Rated Current output 172 Amps
Rated frequency 50 Hz
Heat dissipation of panel 850 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 250A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision

Rapper control system is designed specifically for ESP application. This rapper control system is designed to be used with electrical solenoid type impact rappers. These rappers are also called as magnetic impulse gravity impact (MIGI) rappers. Field installed RDB panel has provided with special type of diode.

  • PLC based rapper systems
  • 7″ Touchscreen HMI for operation.
  • Matrix type & Non matrix type configuration
  • Open communication protocol interface with plant DCS systems.
  • Easy maintenance
  • Suitable for ESP application in industries like Sugar plant, Cement plant, steel plant, Power plant, etc.
RECTIFIER/ TR SET 95KVP/1500mA
Make Autodata
Type TR-95/1500
Power 154.3 kVA
Rated Primary Voltage 415 V
Suitable for Voltage variation ±10%
Rated primary Current 215 Amps
Rated Frequency 50 Hz
Suitable for Frequency variation ± 5%
No of phases primary 3-ph
Output Voltage 95 kVP DC at no load
Output Current 1500 mA
Output Power 142.5 kW
Efficiency 93%
No. of Primary taps supplied Nil
Tap Voltage Not applicable
1 minute power frequency withstand voltage 3 kV
Impulse withstand voltage 170 kVP (Only for transformer)
% of impedance system 33 % ±10%
Enclosure protection IP 55
Transformation Ratio 97.8
Form factor Voltage – 0.74,Current – 0.82
Type of Cooling ONAN
Type of Oil Mineral Oil as per IS:335
Total oil requirement (approx.) 770litres
Dielectric strength of oil (with 2.5mm) 60 kV
Flash Point of oil >140°C
Type of oil level gauge Sight Glass
No Load losses at expected operating voltage 1500 W (Subject to IS tolerance)
Load losses (Short Circuit) 5500 W (Subject to IS tolerance)
Miscellaneous losses if any 2200 W
Class of Insulation Class A
TR Unit construction Hermetically sealed without conservator without breather
HT Bushing orientation Horizontal
Earthing Switch External Manual
Class of insulating winding
(I) L.V. Class A
(II) H.V. Class B
Range of Oil Temperature Indicator 0° C – 120° C
Class of L.V. bushing 1.1 kV Class
Class of H.V bushing Suitable for 95 kVP DC
Creepage distance of HV Bushing Min. 750 mm
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns > 60 microns
List of TR set Protection Pressure Release Valve
Oil Temp. Indicator – I – Alarm
Oil Temp. Indicator – II – Trip
Pressure High – Trip
Low Oil Level – Trip
TR set Grounded – Trip
RECTIFIER
Type Full Wave Bridge
Make Autodata
Diode type Avalanche Diode
Rating 142.5 kW
Half wave/full wave rectification Full wave rectification
Rated current output of each rectifier set 1500 mA
Rated voltage output of each rectifier set 95kV Peak at no load
Peak inverse voltage of diode bridge 226 kV
No of Earthing terminal 2
Voltage feedback 10VDC at rated kV peak
Current feedback 5V DC at rated average current
TR Control Panel
Make Autodata
Type TRCC 95/1500
Rated voltage output 415 V
Rated Current output 215 Amps
Rated frequency 50 Hz
Heat dissipation of panel 1000 W
Panel enclosure protection IP 42
Suitable for Voltage variation ±10%
Suitable for Frequency variation ±5%
Thyristor rating Min. 330A
Type of over voltage protector G. D. Tube
No. Of Earthing terminal 2
Paint Shade RAL 7032, Siemens Grey
Painting thickness in microns >50 microns
Controller Calculus
Communication


HMI


Built in Rapper provision